Skip to content

Commit

Permalink
for central air-sourced heat pump use name plate efficiency
Browse files Browse the repository at this point in the history
  • Loading branch information
fneum committed Aug 30, 2024
1 parent 56426aa commit b2faf8d
Show file tree
Hide file tree
Showing 9 changed files with 18 additions and 11 deletions.
6 changes: 6 additions & 0 deletions docs/release_notes.rst
Original file line number Diff line number Diff line change
Expand Up @@ -5,6 +5,12 @@ Release Notes
.. Upcoming Release
.. ================
Technology-Data 0.9.2 (30 August 2024)
======================================

* for central air-sourced heat pump use name plate efficiency

Technology-Data 0.9.1 (7 August 2024)
=====================================

Expand Down
2 changes: 1 addition & 1 deletion outputs/costs_2020.csv
Original file line number Diff line number Diff line change
Expand Up @@ -633,7 +633,7 @@ cement capture,investment,3000000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
central air-sourced heat pump,FOM,0.2102,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
central air-sourced heat pump,VOM,2.3175,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
central air-sourced heat pump,efficiency,3.4,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
central air-sourced heat pump,efficiency,3.1,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
central air-sourced heat pump,investment,1006.7765,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0
Expand Down
2 changes: 1 addition & 1 deletion outputs/costs_2025.csv
Original file line number Diff line number Diff line change
Expand Up @@ -633,7 +633,7 @@ cement capture,investment,2800000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
central air-sourced heat pump,FOM,0.2102,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
central air-sourced heat pump,VOM,2.3175,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
central air-sourced heat pump,efficiency,3.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
central air-sourced heat pump,efficiency,3.15,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
central air-sourced heat pump,investment,1006.7765,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0
Expand Down
2 changes: 1 addition & 1 deletion outputs/costs_2030.csv
Original file line number Diff line number Diff line change
Expand Up @@ -633,7 +633,7 @@ cement capture,investment,2600000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
central air-sourced heat pump,VOM,2.6561,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
central air-sourced heat pump,efficiency,3.6,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
central air-sourced heat pump,efficiency,3.2,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0
Expand Down
2 changes: 1 addition & 1 deletion outputs/costs_2035.csv
Original file line number Diff line number Diff line change
Expand Up @@ -633,7 +633,7 @@ cement capture,investment,2400000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
central air-sourced heat pump,VOM,2.4868,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
central air-sourced heat pump,efficiency,3.625,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
central air-sourced heat pump,efficiency,3.25,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0
Expand Down
2 changes: 1 addition & 1 deletion outputs/costs_2040.csv
Original file line number Diff line number Diff line change
Expand Up @@ -633,7 +633,7 @@ cement capture,investment,2200000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
central air-sourced heat pump,VOM,2.3175,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
central air-sourced heat pump,efficiency,3.65,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
central air-sourced heat pump,efficiency,3.3,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0
Expand Down
2 changes: 1 addition & 1 deletion outputs/costs_2045.csv
Original file line number Diff line number Diff line change
Expand Up @@ -633,7 +633,7 @@ cement capture,investment,2000000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
central air-sourced heat pump,VOM,2.5715,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
central air-sourced heat pump,efficiency,3.675,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
central air-sourced heat pump,efficiency,3.35,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0
Expand Down
2 changes: 1 addition & 1 deletion outputs/costs_2050.csv
Original file line number Diff line number Diff line change
Expand Up @@ -633,7 +633,7 @@ cement capture,investment,1800000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
central air-sourced heat pump,VOM,2.8255,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
central air-sourced heat pump,efficiency,3.7,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
central air-sourced heat pump,efficiency,3.4,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0
Expand Down
9 changes: 5 additions & 4 deletions scripts/compile_cost_assumptions.py
Original file line number Diff line number Diff line change
Expand Up @@ -1294,16 +1294,17 @@ def order_data(tech_data):
(df.unit =="MWh_e/MWh_th") |
(df.unit =="MWh_th/MWh_th") |
(df.unit =='MWh/MWh Total Input') |
df.unit.str.contains("MWh_FT/MWh_H2"))
& (~df.index.str.contains("name plate"))].copy()
df.unit.str.contains("MWh_FT/MWh_H2"))].copy()

if tech == 'Fischer-Tropsch':
efficiency[years] *= 100


# take annual average instead of name plate efficiency
if any(efficiency.index.str.contains("annual average")):
# take annual average instead of name plate efficiency, unless central air-sourced heat pump
if any(efficiency.index.str.contains("annual average")) and tech != "central air-sourced heat pump":
efficiency = efficiency[efficiency.index.str.contains("annual average")]
elif any(efficiency.index.str.contains("name plate")):
efficiency = efficiency[efficiency.index.str.contains("name plate")]

# hydrogen electrolysiswith recoverable heat
heat_recovery_label = "hereof recoverable for district heating"
Expand Down

0 comments on commit b2faf8d