VSTestResult does not report startTime #359
Labels
Comments
Yes, this can be approximated today for v1 & v2 tests with the arrival of the start message. We would just need to stash that information away so it could be retrieved when creating the VSTest For v3, we can add this explicitly (we were already planning to do this with assembly starting, but it can be easily added for all start messages). |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Trx includes StartTime and EndTime, and VSTest sets those values to the current timestamp for "backward compatibility". Xunit does not report start time or end time, just duration.
Would you be open to start tracking this information? I can make a PR.
visualstudio.xunit/src/xunit.runner.visualstudio/Sinks/VsExecutionSink.cs
Line 274 in b0b4704
https://github.com/microsoft/vstest/blob/b2e2126f1aa7e5753cafe9515563c99ade6a59ce/src/Microsoft.TestPlatform.ObjectModel/TestResult.cs#L34
The text was updated successfully, but these errors were encountered: