From b2faf8d3e432099bd2669bd1e3706ed472bf0768 Mon Sep 17 00:00:00 2001 From: Fabian Neumann Date: Fri, 30 Aug 2024 15:20:45 +0200 Subject: [PATCH] for central air-sourced heat pump use name plate efficiency --- docs/release_notes.rst | 6 ++++++ outputs/costs_2020.csv | 2 +- outputs/costs_2025.csv | 2 +- outputs/costs_2030.csv | 2 +- outputs/costs_2035.csv | 2 +- outputs/costs_2040.csv | 2 +- outputs/costs_2045.csv | 2 +- outputs/costs_2050.csv | 2 +- scripts/compile_cost_assumptions.py | 9 +++++---- 9 files changed, 18 insertions(+), 11 deletions(-) diff --git a/docs/release_notes.rst b/docs/release_notes.rst index 099c02a..9c6bbea 100644 --- a/docs/release_notes.rst +++ b/docs/release_notes.rst @@ -5,6 +5,12 @@ Release Notes .. Upcoming Release .. ================ + +Technology-Data 0.9.2 (30 August 2024) +====================================== + +* for central air-sourced heat pump use name plate efficiency + Technology-Data 0.9.1 (7 August 2024) ===================================== diff --git a/outputs/costs_2020.csv b/outputs/costs_2020.csv index db63b76..ce9a555 100644 --- a/outputs/costs_2020.csv +++ b/outputs/costs_2020.csv @@ -633,7 +633,7 @@ cement capture,investment,3000000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0 central air-sourced heat pump,FOM,0.2102,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0 central air-sourced heat pump,VOM,2.3175,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0 -central air-sourced heat pump,efficiency,3.4,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0 +central air-sourced heat pump,efficiency,3.1,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0 central air-sourced heat pump,investment,1006.7765,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0 central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0 central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0 diff --git a/outputs/costs_2025.csv b/outputs/costs_2025.csv index eb8fe67..5a98dcc 100644 --- a/outputs/costs_2025.csv +++ b/outputs/costs_2025.csv @@ -633,7 +633,7 @@ cement capture,investment,2800000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0 central air-sourced heat pump,FOM,0.2102,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0 central air-sourced heat pump,VOM,2.3175,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0 -central air-sourced heat pump,efficiency,3.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0 +central air-sourced heat pump,efficiency,3.15,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0 central air-sourced heat pump,investment,1006.7765,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0 central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0 central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0 diff --git a/outputs/costs_2030.csv b/outputs/costs_2030.csv index a31d739..593fbcd 100644 --- a/outputs/costs_2030.csv +++ b/outputs/costs_2030.csv @@ -633,7 +633,7 @@ cement capture,investment,2600000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0 central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0 central air-sourced heat pump,VOM,2.6561,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0 -central air-sourced heat pump,efficiency,3.6,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0 +central air-sourced heat pump,efficiency,3.2,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0 central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0 central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0 central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0 diff --git a/outputs/costs_2035.csv b/outputs/costs_2035.csv index dee4047..546eb17 100644 --- a/outputs/costs_2035.csv +++ b/outputs/costs_2035.csv @@ -633,7 +633,7 @@ cement capture,investment,2400000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0 central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0 central air-sourced heat pump,VOM,2.4868,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0 -central air-sourced heat pump,efficiency,3.625,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0 +central air-sourced heat pump,efficiency,3.25,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0 central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0 central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0 central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0 diff --git a/outputs/costs_2040.csv b/outputs/costs_2040.csv index e7f9ffb..cf5c2cb 100644 --- a/outputs/costs_2040.csv +++ b/outputs/costs_2040.csv @@ -633,7 +633,7 @@ cement capture,investment,2200000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0 central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0 central air-sourced heat pump,VOM,2.3175,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0 -central air-sourced heat pump,efficiency,3.65,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0 +central air-sourced heat pump,efficiency,3.3,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0 central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0 central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0 central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0 diff --git a/outputs/costs_2045.csv b/outputs/costs_2045.csv index 0828e21..07705c2 100644 --- a/outputs/costs_2045.csv +++ b/outputs/costs_2045.csv @@ -633,7 +633,7 @@ cement capture,investment,2000000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0 central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0 central air-sourced heat pump,VOM,2.5715,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0 -central air-sourced heat pump,efficiency,3.675,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0 +central air-sourced heat pump,efficiency,3.35,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0 central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0 central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0 central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0 diff --git a/outputs/costs_2050.csv b/outputs/costs_2050.csv index 0bf0ad9..bad2a25 100644 --- a/outputs/costs_2050.csv +++ b/outputs/costs_2050.csv @@ -633,7 +633,7 @@ cement capture,investment,1800000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0 central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0 central air-sourced heat pump,VOM,2.8255,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0 -central air-sourced heat pump,efficiency,3.7,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0 +central air-sourced heat pump,efficiency,3.4,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0 central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0 central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0 central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0 diff --git a/scripts/compile_cost_assumptions.py b/scripts/compile_cost_assumptions.py index 206339c..b53005e 100644 --- a/scripts/compile_cost_assumptions.py +++ b/scripts/compile_cost_assumptions.py @@ -1294,16 +1294,17 @@ def order_data(tech_data): (df.unit =="MWh_e/MWh_th") | (df.unit =="MWh_th/MWh_th") | (df.unit =='MWh/MWh Total Input') | - df.unit.str.contains("MWh_FT/MWh_H2")) - & (~df.index.str.contains("name plate"))].copy() + df.unit.str.contains("MWh_FT/MWh_H2"))].copy() if tech == 'Fischer-Tropsch': efficiency[years] *= 100 - # take annual average instead of name plate efficiency - if any(efficiency.index.str.contains("annual average")): + # take annual average instead of name plate efficiency, unless central air-sourced heat pump + if any(efficiency.index.str.contains("annual average")) and tech != "central air-sourced heat pump": efficiency = efficiency[efficiency.index.str.contains("annual average")] + elif any(efficiency.index.str.contains("name plate")): + efficiency = efficiency[efficiency.index.str.contains("name plate")] # hydrogen electrolysiswith recoverable heat heat_recovery_label = "hereof recoverable for district heating"