Multiplus reports sometimes strange wrong values #45

Open
naofireblade opened this issue Mar 19, 2024 · 3 comments
Open

Multiplus reports sometimes strange wrong values #45

naofireblade opened this issue Mar 19, 2024 · 3 comments

Comments

@naofireblade
Copy link

naofireblade commented Mar 19, 2024

Hi, some times when switched off the Multiplus (VE.BUS) reports 262.143W instead of 0W for ACTIVE_AC_IN_POWER and AC_OUT_POWER. Also the text_sensor DEVICE_STATE is 255 instead of 'off'.

Other values from the Multiplus like BATTERY_VOLTAGE are correct.

Switching the Multiplus on or to charging only, solves the problem.

Values on the Cerbo GX are correct at any time.

@Fabian-Schmidt
Copy link
Owner

Thanks for the report. I will look into it on the weekend.

Fabian-Schmidt pushed a commit that referenced this issue Mar 22, 2024
@Fabian-Schmidt
Copy link
Owner

Hi,
I added handling for these cases. The sensor is transmit NAN (Not a number) now.

@Fabian-Schmidt
Copy link
Owner

Is this issue resolved? Can I close it?